{"id":822,"date":"2017-10-23T04:24:36","date_gmt":"2017-10-23T04:24:36","guid":{"rendered":"http:\/\/demo.zozothemes.com\/induzy\/?page_id=822"},"modified":"2019-10-24T14:17:09","modified_gmt":"2019-10-24T14:17:09","slug":"iso-iec-17025-accredited-calibration-scope","status":"publish","type":"page","link":"https:\/\/www.mudiame.com\/ng\/iso-iec-17025-accredited-calibration-scope\/","title":{"rendered":"ISO\/IEC 17025 Accredited Calibration Scope"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<\/p>\n<h2 style=\"text-align: center;\">ACCREDITED CALIBRATION SCOPE<\/h2>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th>MEASUREMENT AREA<\/th>\n<th>RANGE &amp; RESOLUTION<\/th>\n<th>CALIBRATION &amp; MEASUREMENT CAPABILITY1 (CMC) (\u00b1)<\/th>\n<th>TECHNIQUE, REFERENCE STANDARD, EQUIPMENT<\/th>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\">Dimensional<\/td>\n<\/tr>\n<tr>\n<td>Calipers<\/td>\n<td>0-300 mm\/0.01 mm<\/td>\n<td>12 \u00b5m<\/td>\n<td>Grade \u20180\u2019 Gage Blocks<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Micrometers<\/td>\n<td>0-25 mm\/0.001 mm<\/td>\n<td>1.5 \u00b5m<\/td>\n<td rowspan=\"2\">Grade \u20180\u2019 Gage Blocks<\/td>\n<\/tr>\n<tr>\n<td>0-25 mm\/0.001 mm<\/td>\n<td>40 \u00b5m<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Pin guages\/plug Guages\/Measuring Wires<\/td>\n<td>Up to 10 mm<\/td>\n<td>2.5 \u00b5m<\/td>\n<td>Master Digital Micrometer<\/td>\n<\/tr>\n<tr>\n<td>Scales and Balances<\/td>\n<td>0.300 kg<\/td>\n<td>0.015% IR<\/td>\n<td>Classes M1 and Weights (Masses)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\">Electrical\/DC\/Low Frequency<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Voltage &#8211; DC<\/td>\n<td>Up to 6 V\/1 mV<\/td>\n<td>0.59 mV<\/td>\n<td rowspan=\"4\">Multi-functional Calibrator (Fluke 9100);<br \/>\nPrecision Multi Product Calibrator (Transmile 3041A);<br \/>\nElectrical Test Equipment Calibrator (Transmile 3200)<\/td>\n<\/tr>\n<tr>\n<td>Up to 60 V\/10 mV<\/td>\n<td>5.81 mV<\/td>\n<\/tr>\n<tr>\n<td>Up to 600 V\/0.1 V<\/td>\n<td>0.058 V<\/td>\n<\/tr>\n<tr>\n<td>Up to 1000 V\/1 V<\/td>\n<td>0.577 V<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Voltage &#8211; AC<\/td>\n<td>Up to 6 V\/1 mV<\/td>\n<td>2.5 mV<\/td>\n<td rowspan=\"4\">Multi-functional Calibrator (Fluke 9100);<br \/>\nPrecision Multi Product Calibrator (Transmile 3041A);<br \/>\nElectrical Test Equipment Calibrator (Transmile 3200)<\/td>\n<\/tr>\n<tr>\n<td>Up to 60 V\/10 mV<\/td>\n<td>24.7 mV<\/td>\n<\/tr>\n<tr>\n<td>Up to 600 V\/0.1 V<\/td>\n<td>0.16 V<\/td>\n<\/tr>\n<tr>\n<td>Up to 1000 V\/1<\/td>\n<td>0.62 V<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">Current Dc<\/td>\n<td>Up to 200 mA\/0.1 mA<\/td>\n<td>0.06 mA<\/td>\n<td rowspan=\"6\">Multi-functional Calibrator (Fluke 9100);<br \/>\nPrecision Multi Product Calibrator (Transmile 3041A);<br \/>\nElectrical Test Equipment Calibrator (Transmile 3200)<\/td>\n<\/tr>\n<tr>\n<td>Up to 2 A\/1 mA<\/td>\n<td>0.59 mA<\/td>\n<\/tr>\n<tr>\n<td>Up to 6 A\/1 mA<\/td>\n<td>0.76 mA<\/td>\n<\/tr>\n<tr>\n<td>Up to 10 A\/10 mA<\/td>\n<td>5.8 mA<\/td>\n<\/tr>\n<tr>\n<td>Up to 100 A\/0.1 A<\/td>\n<td>0.12 A<\/td>\n<\/tr>\n<tr>\n<td>Up to 500 A\/0.1 A<\/td>\n<td>1.1 A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">Current Dc<\/td>\n<td>Up to 200 mA\/0.1 mA<\/td>\n<td>0.07 mA<\/td>\n<td rowspan=\"8\">Multi-functional Calibrator (Fluke 9100);<br \/>\nPrecision Multi Product Calibrator (Transmile 3041A);<br \/>\nElectrical Test Equipment Calibrator (Transmile 3200)<\/td>\n<\/tr>\n<tr>\n<td>Up to 2 A\/1 mA<\/td>\n<td>0.77<\/td>\n<\/tr>\n<tr>\n<td>Up to 6 A\/1 mA<\/td>\n<td>5.1 mA<\/td>\n<\/tr>\n<tr>\n<td>Up to 10 A\/10 mA<\/td>\n<td>7.7 mA<\/td>\n<\/tr>\n<tr>\n<td>Up to 100 A\/0.1 A<\/td>\n<td>0.12 A<\/td>\n<\/tr>\n<tr>\n<td>Up to 500 A\/0.1 A<\/td>\n<td>1.1 A<\/td>\n<\/tr>\n<tr>\n<td>Up to 1000 A\/0.1 A<\/td>\n<td>1.2 A<\/td>\n<\/tr>\n<tr>\n<td>Up to 1500 A\/1 A<\/td>\n<td>1.4 A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\">Electrical\/DC\/Low Frequency<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">Insulation &#8211; Resistance<\/td>\n<td>Up to 1 ?<\/td>\n<td>\u00b1 300 \u00b5?<\/td>\n<td rowspan=\"8\">Electrical Test Equipment Calibrator<br \/>\n(Transmille 3200); Transmille 15kV<br \/>\nInsulation Adapter<br \/>\nPrecision Microproduct Calibrator<br \/>\n(Transmile 3041A)<\/td>\n<\/tr>\n<tr>\n<td>Up to 1 k?<\/td>\n<td>\u00b1 20 m?<\/td>\n<\/tr>\n<tr>\n<td>Up to 40 k?<\/td>\n<td>\u00b1 0.95 ?<\/td>\n<\/tr>\n<tr>\n<td>Up to 1 M?<\/td>\n<td>\u00b1 25 ?<\/td>\n<\/tr>\n<tr>\n<td>Up to 10 M?<\/td>\n<td>\u00b1 1 k?<\/td>\n<\/tr>\n<tr>\n<td>Up to 100 M?<\/td>\n<td>\u00b1 70 k?<\/td>\n<\/tr>\n<tr>\n<td>Up to 1 G?<\/td>\n<td>\u00b1 9 M?<\/td>\n<\/tr>\n<tr>\n<td>Up to 2 G?<\/td>\n<td>\u00b1 9.8 M?<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\">Mechanical<\/td>\n<\/tr>\n<tr>\n<td>Pressure Guages\/Pressure Transducer<\/td>\n<td>0-700 bar\/0.1 bar<\/td>\n<td>0.75% IR<\/td>\n<td>Pressure Comparator; Hydraulic Dead Weight Tester; Master Digital Pressure Guage<\/td>\n<\/tr>\n<tr>\n<td>Pneumatic Guages<\/td>\n<td>Up to 40 bar<\/td>\n<td>0.3% IR<\/td>\n<td>Pneumatic Pressure Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Pressure Chart Recorder<\/td>\n<td>Up to 1000 bar\/1 bar<\/td>\n<td>0.8% IR<\/td>\n<td>Pressure Comparator; Hydraulic Dead Weight Tester; Master Digital Pressure Guage<\/td>\n<\/tr>\n<tr>\n<td>Pneumatic Pressure Calibrator<\/td>\n<td>Up to 40 bar<\/td>\n<td>0.3% IR<\/td>\n<td>Master Guage<\/td>\n<\/tr>\n<tr>\n<td>Universal Testing Machine\/ Hydraulic Compression Machine<\/td>\n<td>0-2500 kN<\/td>\n<td>0.2% IR<\/td>\n<td>Master Load cell (Maccklow Smith)<\/td>\n<\/tr>\n<tr>\n<td>Toque Wrench<\/td>\n<td>Up to 200 Nm<\/td>\n<td>0.9% IR<\/td>\n<td>Electronic Torque Calibrator (Nobar &#8211; Trchek)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\">Thermal<\/td>\n<\/tr>\n<tr>\n<td>Infrared Thermometer<\/td>\n<td>35 &#8211; 500\u00baC Nm<\/td>\n<td>0.8\u00baC<\/td>\n<td>Fluke 4181<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple Type &#8216;K&#8217;<\/td>\n<td>50 &#8211; 1200\u00baC Nm<\/td>\n<td>1.6% IR<\/td>\n<td>Presys T-1200 Dry Block<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Digital Thermometer<\/td>\n<\/tr>\n<tr>\n<td>-50 &#8211; 0\u00baC<\/td>\n<td>0.33\u00baC<\/td>\n<td rowspan=\"2\">Precision Multi Product Calibrator<br \/>\n(Transmille 3041A)<\/td>\n<\/tr>\n<tr>\n<td>&gt; 0 &#8211; 700\u00baC<\/td>\n<td>&gt; 0.31\u00baC<\/td>\n<\/tr>\n<tr>\n<td>&gt;700 &#8211; 1300\u00baC<\/td>\n<td>&gt; 1.13\u00baC<\/td>\n<td>Multi Functionnal Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Ovens and Furnances<\/td>\n<td>Up to 55\u00baC<\/td>\n<td>1\u00baC<\/td>\n<td>Thermocouple Type &#8216;K&#8217;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] ACCREDITED CALIBRATION SCOPE MEASUREMENT AREA RANGE &amp; RESOLUTION CALIBRATION &amp; MEASUREMENT CAPABILITY1 (CMC) (\u00b1) TECHNIQUE, REFERENCE STANDARD, EQUIPMENT Dimensional Calipers 0-300 mm\/0.01 mm 12 \u00b5m Grade \u20180\u2019 Gage Blocks Micrometers 0-25 mm\/0.001 mm 1.5 \u00b5m Grade \u20180\u2019 Gage Blocks 0-25 mm\/0.001 mm 40 \u00b5m Pin guages\/plug Guages\/Measuring Wires Up to 10 mm 2.5 \u00b5m<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-822","page","type-page","status-publish","hentry"],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.mudiame.com\/ng\/wp-json\/wp\/v2\/pages\/822","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mudiame.com\/ng\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mudiame.com\/ng\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mudiame.com\/ng\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mudiame.com\/ng\/wp-json\/wp\/v2\/comments?post=822"}],"version-history":[{"count":3,"href":"https:\/\/www.mudiame.com\/ng\/wp-json\/wp\/v2\/pages\/822\/revisions"}],"predecessor-version":[{"id":3474,"href":"https:\/\/www.mudiame.com\/ng\/wp-json\/wp\/v2\/pages\/822\/revisions\/3474"}],"wp:attachment":[{"href":"https:\/\/www.mudiame.com\/ng\/wp-json\/wp\/v2\/media?parent=822"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}